View Issue Details
ID | Project | Category | View Status | Date Submitted | Last Update |
---|---|---|---|---|---|
0002433 | SkyChart | 1-Software | public | 21-05-04 01:03 | 21-05-04 08:51 |
Reporter | Garth | Assigned To | |||
Priority | normal | Severity | minor | Reproducibility | always |
Status | resolved | Resolution | fixed | ||
Platform | PC | OS | Windows | OS Version | 10 64bit |
Product Version | 4.2 | ||||
Summary | 0002433: Error when opening "ASCOM telescope interface" dialog | ||||
Description | After connecting to a telescope, clicking Hide, or closing out of the ASCOM telescope interface dialog, then returning to it, an error dialog will show reporting "Cannot focus a disabled or invisible window. Press OK to ignore and risk data corruption. Press Abort to kill the program." Clicking OK dismisses the error dialog and thing seem to continue to function. Clicking Abort does exit the software. Error only seems to occur when returning to the ASCOM telescope interface dialog with an active telescope connection. | ||||
Steps To Reproduce | Steps that don't cause the error. 1) Open skychart. 2) Click the "Connect telescope" button, or choose "Connect telescope" from the Telescope menu to show the ASCOM telescope interface dialog. 3) Click Hide, or close the dialog. 4) Repeat 2-3 without error as much as needed. Steps that cause the error 1) Open skychart. 2) Click the "Connect telescope" button, or choose "Connect telescope" from the Telescope menu to show the ASCOM telescope interface dialog. 3) Connect to the telescope. 4) Click Hide, or close the dialog. 5) Click the "Connect telescope" button, or choose "Connect telescope" from the Telescope menu to show the ASCOM telescope interface dialog. 6) Error dialog is shown. 7) Click OK to dismiss the error dialog. 8) Repeat 2-7 as many times as desired to repeat the error. 9) Click the "Connect telescope" button, or choose "Connect telescope" from the Telescope menu to show the ASCOM telescope interface dialog. 10) Error dialog is shown. Click OK to dismiss. 11) Click the Disconnect button 12) Click Hide, or close the dialog. 14) Click the "Connect telescope" button, or choose "Connect telescope" from the Telescope menu to show the ASCOM telescope interface dialog. 15) *no error* | ||||
Tags | No tags attached. | ||||
|
|
|
This issue is already fixed in the 4.3 beta version. Please install this version from https://sourceforge.net/projects/skychart/files/0-beta/ |
Date Modified | Username | Field | Change |
---|---|---|---|
21-05-04 01:03 | Garth | New Issue | |
21-05-04 01:03 | Garth | File Added: toggling telescope.png | |
21-05-04 08:51 | Patrick Chevalley | Status | new => resolved |
21-05-04 08:51 | Patrick Chevalley | Resolution | open => fixed |
21-05-04 08:51 | Patrick Chevalley | Description Updated | |
21-05-04 08:51 | Patrick Chevalley | Steps to Reproduce Updated | |
21-05-04 08:51 | Patrick Chevalley | Note Added: 0007087 |