View Issue Details
| ID | Project | Category | View Status | Date Submitted | Last Update |
|---|---|---|---|---|---|
| 0000268 | SkyChart | 1-Software | public | 07-06-07 19:48 | 08-09-18 08:01 |
| Reporter | marc fokker | Assigned To | Patrick Chevalley | ||
| Priority | normal | Severity | major | Reproducibility | always |
| Status | closed | Resolution | fixed | ||
| Platform | x86 | OS | Windows | OS Version | XP |
| Product Version | 3.0.1.3 SVN | ||||
| Summary | 0000268: Setting Simulation parameters problematic | ||||
| Description | Changing the value in 'number of steps' or the 'every' field quite often isn't saved, sometimes the result is access violation. Most probably releated to issue 267. | ||||
| Steps To Reproduce | Please open from the menu-bar 'Setup > Date/Time' In the panel choose the 'Simulation' tab. Change the value by pre- or postfixing digits, or try using the small arrows. | ||||
| Tags | No tags attached. | ||||
| duplicate of | 0000267 | closed | Patrick Chevalley | Setting and saving time is problematic |
|
|
Same as 0000267 |
| Date Modified | Username | Field | Change |
|---|---|---|---|
| 07-06-07 19:48 | marc fokker | New Issue | |
| 07-06-10 13:20 | Patrick Chevalley | Relationship added | duplicate of 0000267 |
| 07-06-10 13:20 | Patrick Chevalley | Duplicate ID | 0 => 267 |
| 07-06-10 13:20 | Patrick Chevalley | Status | new => resolved |
| 07-06-10 13:20 | Patrick Chevalley | Resolution | open => fixed |
| 07-06-10 13:20 | Patrick Chevalley | Assigned To | => Patrick Chevalley |
| 07-06-10 13:20 | Patrick Chevalley | Note Added: 0000439 | |
| 08-09-18 08:01 | Patrick Chevalley | Status | resolved => closed |