View Issue Details
| ID | Project | Category | View Status | Date Submitted | Last Update |
|---|---|---|---|---|---|
| 0000932 | SkyChart | 1-Software | public | 12-01-18 23:24 | 12-03-04 19:26 |
| Reporter | Bernd | Assigned To | Patrick Chevalley | ||
| Priority | normal | Severity | minor | Reproducibility | always |
| Status | closed | Resolution | no change required | ||
| Platform | x86 | OS | Windows | OS Version | Vista |
| Product Version | 3.4 | ||||
| Summary | 0000932: ASCOM-controlled CdC: cursor-circle (and reference) is not set to referenced star | ||||
| Description | after starting CdC and ASCOM-control I marked a star which I pointed at with the telescope. The cursor-circle is then set to. The next time I mark another star the cursor circle doesn't follow and I cannot tell it to jump to the marked star which I can also see in the telescope. When I select another object near to it and tell the system to goto it makes everything but moving in a senseful way. So it seems to me, that after clicking on a star and say "take it as reference", the cursor circle should be set to this star because this is the real position the telescope is pointing at. The next step is a "goto", so it will make sense. The problem is that it works fine when used once. Using it more than once it fails as described above. BUT despite of that: CdC is REEAALLLL COOOOOOL STUFFFFF ;-) | ||||
| Tags | No tags attached. | ||||
|
|
I am not sure to understand exactly what you do and what you try to do. The steps to operate the telescope (ASCOM or other) is: 1- Make all the telescope and handpad initialization as indicated in your telescope manual. This include 2 or 3 stars alignment. 2- Connect the cable to the computer. 3- Launch CdC, click the menu Telescope / Control panel to show the ASCOM interface. If it not show, open Telescope / settings and select ASCOM. 4- Select your telescope driver and click Configure for details (COM port, ...) 5- Click Connect and Tracking if it is off. 6- If you want a cursor to continuously show the telescope position on the map, open the menu Telescope / Track telescope. 7- To point the telescope to any object, click on the object on the map then menu Telescope / Slew. Please try with this steps and indicate me where something is not working. |
|
|
Hi Patrick, sorry if I confused you with my description, so here is a step by step one: 1. Run CdC and connect to scope 2. Unlock mount screws and center a bright star next to the object to be photographed (and lock screws again ;-) 3. synchronize this star in cdc 4. move to object 5. Take photo 6. Guessing another object to be photographed and do step 2. 7. Doing Step 3. ==> Result: No Cursor circle around synchronized star and step 4. does not work. I hope this description is a bit more precise and thanx for your reply! Bernd |
|
|
OK I better understand, thank you! I do your operation sequence using the ASCOM telescope simulator. It operate about the same, the only thing I can't do is to unlock for manual move but I think this is unimportant as no logical component know of this operation. For me all work fine, I can Sync a star then Slew to object and repeat any number of time without problem. Can you try with the ASCOM telescope simulator instead of your mount driver and give me the result? Also what is your mount model and ASCOM driver you use? |
|
|
Hi Patrick, at this weekend I had some time to reduce the problem as follows: setup: EQMOD with EQ6 on ASCOM6-Platform 1. Run CdC with EQSim and Unpark the scope. Circle and EQSim-position @ RA=16:38 and DE=+90 2. click on gamma Cep and sync ---> no move 3. click on gamma Umi and sync ---> move to new position 4. click on gamma Cep and sync ---> no move 5. click on gamma Dra and sync ---> move to new position Using EQMOD with real mount running ends up in same behaviour. Unclutching the mount, targeting a new star and then clutching the mount again is a often used technique, keeping in mind that the angular motor positions are still pointing to the old target (in case of logical software boundaries...). Perhaps this description gives some hints to my problem. Thanx Bernd |
|
|
I agree this is useful, I used this technique for a long time with my old mount. But the problem here is with EQMOD, not CdC. Click Display+ on the EQMOD handpad to show the messages. When it not move you see the message: Sync Data too big...Ignoring. I don't know why EQMOD do that, you must ask it's developer why it give this message and if there is a way to change this limit. Please try with the Ascom standard simulator (ScopeSim.Telescope) or Simulator for .NET (ASCOM.Simulator.Telescope). It not show this problem and you can Sync anywhere any number of time. |
|
|
I think you must read the chapter about alignment in the EQMOD wiki http://www.welshdragoncomputing.ca/eqmod From what I understand you need to clear all the alignment data each time you unlock and manually move the mount, otherwise it will get completely fooled. Nevertheless there is nothing I can do in CdC about this problem so I close the issue. |
| Date Modified | Username | Field | Change |
|---|---|---|---|
| 12-01-18 23:24 | Bernd | New Issue | |
| 12-01-19 14:47 | Patrick Chevalley | Note Added: 0001904 | |
| 12-01-19 14:47 | Patrick Chevalley | Assigned To | => Patrick Chevalley |
| 12-01-19 14:47 | Patrick Chevalley | Status | new => feedback |
| 12-01-19 14:48 | Patrick Chevalley | Priority | high => normal |
| 12-01-19 14:48 | Patrick Chevalley | Severity | major => minor |
| 12-01-19 19:09 | Bernd | Note Added: 0001905 | |
| 12-01-19 19:09 | Bernd | Status | feedback => assigned |
| 12-01-20 23:06 | Patrick Chevalley | Note Added: 0001907 | |
| 12-01-20 23:06 | Patrick Chevalley | Status | assigned => feedback |
| 12-01-22 20:17 | Bernd | Note Added: 0001912 | |
| 12-01-22 20:17 | Bernd | Status | feedback => assigned |
| 12-01-22 21:51 | Patrick Chevalley | Note Added: 0001913 | |
| 12-01-22 21:51 | Patrick Chevalley | Status | assigned => feedback |
| 12-01-24 19:07 | Patrick Chevalley | Note Added: 0001918 | |
| 12-01-24 19:07 | Patrick Chevalley | Status | feedback => resolved |
| 12-01-24 19:07 | Patrick Chevalley | Resolution | open => no change required |
| 12-03-04 19:26 | Patrick Chevalley | Status | resolved => closed |